Ion Selective Electrode Instruments

Print Friendly

The Labfit Range of ISE Instrumentation

We have Ion Selective Electrode instruments for, Ammonia, Chloride, Fluoride & Nitrate and they can all be used on Aqueous solutions like water, waste water etc. With our software, you can truly customize the methodology as we give you the tools to adjust, configure and control the quality of your samples. Our ISE automated instruments are not limited to the standard methods listed under each product because of our features and settings available to you in the method setup configuration.

AS3210 Ammonia ISE Analyzer

Ammonia ISE ElectrodeThe Labfit AS3210 Ammonia Analyzer is suitable for many application including; water, waster water, wines, juices and soil samples. The AS3210 Ammonia Analyzer is the ideal solution for environmental monitoring and is accurate to your method configuration. The AS3210 Ammonia Analyzer is also inexpensive compared to other instrumentation while still maintaining sample accuracy. Using the Ion Strength Adjuster solution for the ISE probe the AS3210 Ammonia Analyzer effectively titrates to an end point determined by the electrode. Find out more today!

AS3220 Nitrate ISE Analyzer

Preparing Samples ready ISEWhy use expensing Ion Chromatography or Flow Injection Instrumentation when an Ion Selective Electrode can do the job just as accurately? The Labfit AS3220 Nitrate Analyzer utilizes accurate syringe pumps to inject an Ionic Strength Adjustor solution to prevent ammonia interferences automatically. The AS3220 Nitrate Analyzer includes standards positions for ISE calibration and these positions can be used before or during an Nitrate analysis. The AS3220 Nitrate ISE Analyzer is ideal for water, waste water, sludges etc and is a very affordable cost effective solution to Nitrate analysis. Find out more today!

AS3230 Chloride ISE Analyzer

Automated Chloride ISE AnalyzerWith the Labfit AS3230 Chloride Analyzer measurement is simple, fast, easy to perform, and inexpensive. The Labfit AS3230 Chloride Analyser makes use of the syringe pump to accurately determine the end-point using the Chloride ISE probe through titration. The Intelligence built into our software allows the AS3230 Chloride Analyzer to determine which syringe pump to use when the pH is above or below the configurable setting within the method. The Labfit AS3230 Chloride Analyzer is ideal for water, waste water, and other aqueous solutions. Find out more today!

AS3240 Fluoride ISE Analyzer

On Screen Sample Indication QCThe Labfit AS3240 Fluoride Analyzer is supports many advanced features such as automatic ISA addition, non-violent sample stirring, intelligent automatic ion selective calibration in addition to a large sample capacity of 180 samples. Reduce your sample preparation by automating it. The Labfit AS3240 Fluoride Analyzer automates this critical step an the Fluoride analysis through the use of accurate syringe pumps that have less than 0.01% accuracy. Find out more today!